摘要:
为了解决炼钢炉前快速分析不锈钢中超低碳,该方法采用直读光谱仪对超低碳不锈钢试样进行分析研究,通过对其取样、制样、分析等过程的试验,总结出一系列影响其分析准确度的规律及采取的措施,从而提高了光谱法测定不锈钢中超低碳的分析准确性,并可取代传统的红外法分析。

Abstract: In order to solve the rapid analysis of ultra low carbon in stainless steel before the furnaces, the method used direct-reading spectrometer to analyze ultra-low carbon steel samples. Through studying the samples taken, the samples preparation and analysis process, a series of laws of in-fluencing the analytical accuracy and the measures taken were summed up. Thereby the accuracy of the ultea low carbon in stainless steel was increased by direct reading spectrometry and it could replace the traditional method of infrared analysis.

文章引用: 梁小丽 , 芦 飞 (2014) 提高直读光谱法测定不锈钢中超低碳的准确性。 化学工程与技术, 4, 72-77. doi: 10.12677/HJCET.2014.45010

参考文献

[1] 不锈钢多元素含量的测定火花放电原子发射光谱法(常规法), GB 11170-2008.

[2] 赵海燕, 裴柯兴 (2007) 光谱分析中影响碳量分析的主要因素. 铸造设备研究, 3, 36.

[3] 田桂英 (2003) 普碳钢中含铝量对直读光谱法测定碳的影响. 光谱实验室, 2, 304.

[4] 金建华 (2003) 火花发射光谱仪分析钢中低含量碳. 冶金分析, 5, 56.

[5] 钢铁总碳硫含量的测定高频感应炉燃烧后红外吸收法(常规方法), GB/T 20123-2006.