LNG气瓶阀门低温气密性检测方法研究
A Review of Low-Temperature Air Tightness Detection Technology of LNG Cylinder Valve

作者: 吴 俭 , 李 前 :上海市特种设备监督检验技术研究院,上海;

关键词: LNG气瓶附件低温气密性LNG Cylinder Valve Low Temperature Gas Tightness

摘要:

本文重点对LNG气瓶附件的气密性测试方法进行了研究,通过分析氦质谱检漏法和常低温压差法两种测试方法的优势和弊端,分析了低温气密性测试的关键技术,提出了具体的改进意见,解决了LNG气瓶附件在−196℃低温下进行气密性检测的技术难题

Abstract:
This article focuses on the gas tightness test of LNG cylinder accessories. Through the analysis of the advantages and disadvantages of two kinds of test methods, helium mass spectrometer leak detection method and normal & low temperature differential pressure method, it analyzes the key technology of the low-temperature air tightness test, puts forward the detailed improvement suggestions, and solves the gas tightness test problem of LNG cylinder accessories under the low temperature of −196˚C.

文章引用: 吴 俭 , 李 前 (2014) LNG气瓶阀门低温气密性检测方法研究。 安防技术, 2, 9-12. doi: 10.12677/JSST.2014.22002

参考文献

[1] 中国国家标准化管理委员会 (2011) 固定式真空绝热深冷压力容器. GB/T 18442-2011.

[2] BS EN 1626:2008 (2008) Cryogenic vessels—Valves for cryogenic service.

[3] 中国机械工业联合会 (2010) 低温阀门•技术条件. GB/T 24925-2010.

[4] BS 6364-1998 (1998) Specification for valves for cryogenic service.